How to choose the right fire alarm system

Fire alarm systems

Choosing a fire alarm system isn’t just about adhering to legal requirements; it’s also about saving time, money and effort

There are two common types of fire alarms that businesses use, these are conventional and addressable alarm systems.

Both types of alarm link devices (such as call points and smoke detectors) to a main control panel. The main difference between the two is that with addressable fire alarm systems, you can pinpoint exactly which device has been activated. Whereas a conventional system will only alert the user of which zone has been activated.

How do addressable and conventional alarms differ

Every device connected to the addressable system has its own unique address. When a fire is detected, the device’s address shows up on the main control panel, telling you exactly which device has been activated. This will enable you to find the exact location of a fire and extinguish them quickly.

With a conventional system, there is no way of pinpointing the exact location of the fire. However, by wiring your building into different zones, you can get a general idea of where the fire is. For instance, if you have two floors, you could wire the first as ‘zone 1’ and the second as zone 2. So if a fire occurs in zone 1, you know that the fire is somewhere on the first floor.

Untitled

Wiring differences

Addressable alarm systems connect devices using a loop. This is where one wire connects all devices to the control panel. Both ends of the wire loop connect to the control panel.

With a conventional alarm, each device will be connected to the control panel via its own wire, rather than a shared one. One end of the wire will be touching the device, and another touching the control panel.

Which is the cheaper option for you

Conventional alarm panels cost a lot less to buy but are more expensive to install. This is because each device that is being connected needs its own wire. With addressable systems, one wire loop will connect several devices. This means conventional systems require more wire and more man hours during the installation phase.

Additionally, addressable systems have a range of other facilities that can help save money. For instance, addressable alarm panels monitor the air flow through smoke detectors to prevent the occurrence of false alarms, which can be costly to a business.

Which is more reliable

The addressable alarm panel is also the more reliable of the two. This is because the wire connects to the control panel at both ends (see the diagram above). If one end of the loop becomes severed, signals can still be sent to the control panel via the other end of the loop. Loop isolation modules are also used to separate devices on the loop. This means that if one device becomes disconnected, it won’t disable the circuit. With a conventional system, if a wire has become severed, the device will become disconnected.

How often does it require testing / servicing

A conventional system requires quarterly testing to BS5839 part 1 1988 or 6 monthly for BS5839 part 1 2002 systems. A fire safety log book must be kept beside the alarm panel and any defects or faults must be logged and maintenance recorded within.

This system must also be checked annually including a check of the smoke detectors and alarm cabling.

An addressable alarm system requires 6 monthly checks carried out by a competent BAFE engineer a report printed from the main panel to check for defects and certification issued on completion for a fully functional and safe system.

Overall

Functionally, the addressable fire alarm unit is superior, which can help prevent costly activities and save time when detecting a fire. It’s also cheaper and easier to install. But in terms of buying price, a conventional system is cheaper, and will meet the functional needs of small premises where a sophisticated system is not necessary.

An addressable system would be more suitable in premises such as Schools, Hospitals and large commercial buildings.

[gdlr_styled_box background_color=”#6CACE4″ ]

[gdlr_space height=”-20px”]

[gdlr_text_align class=”center” ]

[gdlr_space height=”-8px”]

[gdlr_heading tag=”h2″ size=”28px” color=”#ffffff” ]Fire Alarms [/gdlr_heading]

[gdlr_space height=”-8px”]

Do you need  help in choosing the right system for your premises?

[gdlr_space height=”30px”]

[gdlr_button href=”http://www.powercor.co.uk/contact.html” target=”_blank” size=”medium” background=”#6CACE4″ color=”#004C97″ with_border=”yes” border_color=”#004C97″]Click here to contact us[/gdlr_button]

[gdlr_space height=”-20px”]

[/gdlr_text_align]

[/gdlr_styled_box]

 

Share the Post:

About

Contact us

Services

LED lighting and controls

Solar and battery storage

Emergency lighting and compliance

Metering and measurement

Power infrastructure

Maintenance

Sectors

Education

Office and industry

Manufacturing and warehouses

Sports

Healthcare

Retail and hospitality

High-end residential

Public sector